U5059-X-2/200-K3L

MBK U5059-X-2/200-K3L MBK METER SOCKET 320A 4TERM LEVER BYPASS W/2 - 200A 2P MCB (REQUIRES S8324)

Page Loading...
Milbank Manufacturing Company
MBK U5059-X-2/200-K3L MBK METER SOCKET 320A 4TERM LEVER BYPASS W/2 - 200A 2P MCB (REQUIRES S8324)
view larger image

Part Description:
Meter Main Combination Meter Socket; Type Ringless; Main Disconnect Type (2) 200 Ampere Circuit Breaker; Service Type Overhead/Underground; Circuit Configuration 1-Phase; Voltage Rating 240 VAC at 60 Hz; Current Rating 320 Ampere; Bypass Switch Type Lever; Number of Jaws 4; Hub Type Large Closing Plate; Knockouts (1) (1/4 Inch - 1/2 Inch), (6) (1 Inch - 1-1/4 Inch - 1-1/2 Inch - 2 Inch - 2-1/2 Inch - 3 Inch) Concentric Knockout, (1) 1/4 Inch Solid Knockout; Enclosure NEMA 3R; Enclosure Material Powder Coated G90 Galvanized Steel; Mounting Surface; Wire Size 4 AWG to 600 KCMIL/(2) 1/0 AWG to 250 KCMIL (Line), 1 AWG to 300 KCMIL (Load); Size 15 Inch W x 4-7/8 Inch D x 42 Inch H; Approval UL; Maximum Current Rating 400 Ampere; Number of Positions 1

UPC:  78457236891

Part Number: 2786038

UNSPSC: 39121102

Status:  STOCK

Create Label

U5059-X-2/200-K3L

MBK U5059-X-2/200-K3L MBK METER SOCKET 320A 4TERM LEVER BYPASS W/2 - 200A 2P MCB (REQUIRES S8324)

MBK U5059-X-2/200-K3L MBK METER SOCKET 320A 4TERM LEVER BYPASS W/2 - 200A 2P MCB (REQUIRES S8324)

MBK U5059-X-2/200-K3L MBK METER SOCKET 320A 4TERM LEVER BYPASS W/2 - 200A 2P MCB (REQUIRES S8324)

78457236891

Specifications

 Approval UL
 Bypass Switch Type Lever
 Circuit Configuration 1-Phase
 Country of Origin United StatesA
 Current Rating REF 320 A
 Enclosure NEMA 3R
 Enclosure Material Powder Coated G90 Galvanized Steel
 Hub Type Large Closing Plate
 Knockouts (1) (1/4 Inch - 1/2 Inch), (6) (1 Inch - 1-1/4 Inch - 1-1/2 Inch - 2 Inch - 2-1/2 Inch - 3 Inch) Concentric Knockout, (1) 1/4 Inch Solid Knockout
 Main Disconnect Type (2) 200 Ampere Circuit Breaker
 Mounting Surface
 Number Of Jaws 4
 Product Class Meter Main Combination Meter Socket
 Service Type Overhead/Underground
 Size Ref 15 IN x 4.88 IN x 42 IN
 Smart Image Thumb 
 Smart Long Desc Meter Main Combination Meter Socket; Type Ringless; Main Disconnect Type (2) 200 Ampere Circuit Breaker; Service Type Overhead/Underground; Circuit Configuration 1-Phase; Voltage Rating 240 VAC at 60 Hz; Current Rating 320 Ampere; Bypass Switch Type Lever; Number of Jaws 4; Hub Type Large Closing Plate; Knockouts (1) (1/4 Inch - 1/2 Inch), (6) (1 Inch - 1-1/4 Inch - 1-1/2 Inch - 2 Inch - 2-1/2 Inch - 3 Inch) Concentric Knockout, (1) 1/4 Inch Solid Knockout; Enclosure NEMA 3R; Enclosure Material Powder Coated G90 Galvanized Steel; Mounting Surface; Wire Size 4 AWG to 600 KCMIL/(2) 1/0 AWG to 250 KCMIL (Line), 1 AWG to 300 KCMIL (Load); Size 15 Inch W x 4-7/8 Inch D x 42 Inch H; Approval UL; Maximum Current Rating 400 Ampere; Number of Positions 1
 Type Ringless
 Voltage Rating REF 240 VAC
 Wire Size 4 AWG to 600 KCMIL/(2) 1/0 AWG to 250 KCMIL (Line), 1 AWG to 300 KCMIL (Load)
 
Loading...
 
Loading...
 
 